Low-voltage single-phase
Solis S6-EH1P hybrid inverter (3–10) kW · single-phase · low voltage
Solis S6-EH1P (3–10 kW) is a new-generation single-phase low-voltage hybrid inverter from the S6 series, designed for residential solar power plants. It works with 48 V batteries (LiFePO₄/lead-acid), supports 2 MPPTs with an input current of up to 16 A per string, delivers instant switchover to backup power (UPS <4 ms) and can be connected in parallel with up to 6 units.
Models
1 / 5
1 / 5
Overview
The Solis S6-EH1P hybrid inverter (3–10 kW) is the optimal choice for residential use and small businesses with standard consumption levels. Spanning 3 to 10 kW with 2 independent MPPT trackers, the range is perfectly suited to private houses, apartments, small offices and cafés, making it easy to arrange PV modules on two opposite roof pitches (East–West, for example).
The core value of this model lies in reliably protecting the site during grid outages. The unit switches to backup power in under 10 milliseconds, keeping sensitive electronics, servers and routers running without interruption. Thanks to its substantial headroom, the inverter handles inrush currents with confidence and easily starts «heavy» household appliances — borehole pumps, refrigerators and air conditioners.
This inverter gets the most out of your solar generation. It allows a PV array to be connected with power headroom to spare and is fully compatible with modern high-density PV modules (input current up to 21 A). The result is active battery charging even in overcast weather or in winter.
Solis S6-EH1P gives complete freedom in choosing storage and expanding the system. The low-voltage range accepts any LiFePO4 or lead-acid batteries (40–60 V) without being locked to a single brand. The inverter integrates flexibly with petrol and diesel generators featuring auto-start, manages loads intelligently to preserve battery charge, and supports parallel connection of up to 6 units for gradual capacity growth.
Key specifications
-
Power range (kW)
3–10
-
Grid phases
Single-phase (220 V)
-
Number of MPPT trackers
2 MPPT
-
Battery voltage
Low voltage — LV (48 V)
-
Built-in monitoring
4G
Key features
-
Supports PV input power of up to 160% of the inverter's rated power, maximising solar energy harvest
-
Supports PV input current of up to 21 A, compatible with future higher-power PV modules
-
200% overload for 10 seconds in off-grid mode, ensuring reliable start-up of motors, water pumps and air conditioners
-
Seamless switching between grid and off-grid modes in under 10 ms for uninterrupted power supply
-
More battery options, compatible with any battery from 40 V to 60 V
-
Supports existing grid-tied solar installations for export control and off-grid operation
-
Multiple generator connection and automatic control methods for flexible on-site deployment
-
Supports up to 6 units in parallel, expanding system capacity
-
Intelligent load management that extends backup runtime for critical loads
-
Configurable battery reserve level for uninterrupted power supply
Technical specifications
Models
SKU: S6-EH1P3K-L-PLUS
DC input (PV side)
- Recommended max. PV array size
- 6 kW
- Recommended max. PV array size
- 7.2 kW
- Recommended max. PV array size
- 9.2 kW
- Recommended max. PV array size
- 10 kW
- Recommended max. PV array size
- 12 kW
- Recommended max. PV array size
- 16 kW
- Recommended max. PV array size
- 18 kW
- Recommended max. PV array size
- 20 kW
- Max. usable PV module input power
- 4.8 kW
- Max. usable PV module input power
- 5.76 kW
- Max. usable PV module input power
- 7.36 kW
- Max. usable PV module input power
- 8 kW
- Max. usable PV module input power
- 9.6 kW
- Max. usable PV module input power
- 12.8 kW
- Max. usable PV module input power
- 14.4 kW
- Max. usable PV module input power
- 16 kW
- Maximum input voltage
- 500 V
- Rated voltage
- 330 V
- Start-up voltage
- 90 V
- MPPT voltage range
- 90 - 435 V
- Max. input current
- 16 A / 16 A
- Max. input current
- 16 A / 16 A
- Max. input current
- 16 A / 16 A
- Max. input current
- 16 A / 16 A
- Max. input current
- 16 A / 16 A
- Max. input current
- 32 A / 32 A
- Max. input current
- 42 A / 42 A
- Max. input current
- 42 A / 42 A
- Max. current at the DC input
- 16 A
- Max. short-circuit current
- 20 A / 20 A
- Max. short-circuit current
- 20 A / 20 A
- Max. short-circuit current
- 20 A / 20 A
- Max. short-circuit current
- 20 A / 20 A
- Max. short-circuit current
- 20 A / 20 A
- Max. short-circuit current
- 40 A / 40 A
- Max. short-circuit current
- 48 A / 48 A
- Max. short-circuit current
- 48 A / 48 A
- Number of MPPTs / max. inputs per MPPT
- 2 / 2
- Number of MPPTs / max. inputs per MPPT
- 2 / 2
- Number of MPPTs / max. inputs per MPPT
- 2 / 2
- Number of MPPTs / max. inputs per MPPT
- 2 / 2
- Number of MPPTs / max. inputs per MPPT
- 2 / 2
- Number of MPPTs / max. inputs per MPPT
- 2 / 4
- Number of MPPTs / max. inputs per MPPT
- 2 / 4
- Number of MPPTs / max. inputs per MPPT
- 2 / 4
Battery
- Battery type
- Lithium-ion / lead-acid
- Battery voltage range
- 40 - 60 V
- Maximum charge / discharge current
- 70 A
- Maximum charge / discharge current
- 80 A
- Maximum charge / discharge current
- 105 A
- Maximum charge / discharge current
- 112 A
- Maximum charge / discharge current
- 135 A
- Maximum charge / discharge current
- 190 A
- Maximum charge / discharge current
- 200 A
- Maximum charge / discharge current
- 210 A
- Number of battery ports / BMS ports
- 1 / 1
- Communication
- CAN / RS485
AC output (grid side)
- Rated output power
- 3 kW
- Rated output power
- 3.6 kW
- Rated output power
- 4.6 kW
- Rated output power
- 5 kW
- Rated output power
- 6 kW
- Rated output power
- 8 kW
- Rated output power
- 9 kW
- Rated output power
- 10 kW
- Max. apparent output power
- 3 kVA
- Max. apparent output power
- 3.6 kVA
- Max. apparent output power
- 4.6 kVA
- Max. apparent output power
- 5 kVA
- Max. apparent output power
- 6 kVA
- Max. apparent output power
- 8 kVA
- Max. apparent output power
- 9 kVA
- Max. apparent output power
- 10 kVA
- Rated grid voltage
- L/N/PE, 220 V / 230 V
- Rated grid frequency
- 50 Hz / 60 Hz
- Rated grid output current
- 13.7 A / 13.1 A
- Rated grid output current
- 16.4 A / 15.7 A
- Rated grid output current
- 20.9 A / 20 A
- Rated grid output current
- 22.8 A / 21.8 A
- Rated grid output current
- 27.3 A / 26.1 A
- Rated grid output current
- 36.4 A / 34.8 A
- Rated grid output current
- 40.9 A / 39.1 A
- Rated grid output current
- 45.5 A / 43.5 A
- Power factor
- > 0.99 (-0.8 to +0.8)
- THDi
- < 3%
AC input (grid side)
- Max. input power
- 4.6 kW
- Max. input power
- 5.5 kW
- Max. input power
- 7 kW
- Max. input power
- 8.8 kW
- Max. input power
- 11 kW
- Max. input power
- 14.3 W
- Input voltage range
- 187 - 253 V
- Max. input current
- 21 A
- Max. input current
- 25 A
- Max. input current
- 29 A
- Max. input current
- 32 A
- Max. input current
- 40 A
- Max. input current
- 50 A
- Max. input current
- 60 A
- Max. input current
- 65 A
AC output (backup output)
- Rated output power
- 3 kW
- Rated output power
- 3.6 kW
- Rated output power
- 4.6 kW
- Rated output power
- 5 kW
- Rated output power
- 6 kW
- Rated output power
- 8 kW
- Rated output power
- 9 kW
- Rated output power
- 10 kW
- Max. apparent output power
- Twice the rated power for 10 seconds
- Backup switchover time
- < 10 ms
- Rated output voltage
- L/N/PE, 220 V / 230 V
- Rated frequency
- 50 Hz / 60 Hz
- Rated output current
- 13.7 A / 13.1 A
- Rated output current
- 16.4 A / 15.7 A
- Rated output current
- 20.9 A / 20 A
- Rated output current
- 22.8 A / 21.8 A
- Rated output current
- 27.3 A / 26.1 A
- Rated output current
- 36.4 A / 34.8 A
- Rated output current
- 40.9 A / 39.1 A
- Rated output current
- 45.5 A / 43.5 A
- Max. AC pass-through current
- 35 A
- Max. AC pass-through current
- 35 A
- Max. AC pass-through current
- 40 A
- Max. AC pass-through current
- 40 A
- Max. AC pass-through current
- 40 A
- Max. AC pass-through current
- 50 A
- Max. AC pass-through current
- 60 A
- Max. AC pass-through current
- 65 A
- THDv (at linear load)
- < 2%
AC input (generator side)
- Max. input power
- 3 kW
- Max. input power
- 3.6 kW
- Max. input power
- 4.6 kW
- Max. input power
- 5 kW
- Max. input power
- 6 kW
- Max. input power
- 8 kW
- Max. input power
- 9 kW
- Max. input power
- 10 kW
- Rated input current
- 13.7 A / 13.1 A
- Rated input current
- 16.4 A / 15.7 A
- Rated input current
- 20.9 A / 20 A
- Rated input current
- 22.8 A / 21.8 A
- Rated input current
- 27.3 A / 26.1 A
- Rated input current
- 36.4 A / 34.8 A
- Rated input current
- 40.9 A / 39.1 A
- Rated input current
- 45.5 A / 43.5 A
- Rated input voltage
- L/N/PE, 220 V / 230 V
- Rated input frequency
- 50 Hz / 60 Hz
Efficiency
- Maximum efficiency
- 96.2%
- European efficiency
- 96.1%
- Max. battery charging efficiency from PV / AC
- 95.3% / 93.9%
- Battery discharge efficiency
- 93.8%
Protection
- Surge protection
- Yes
- Overcurrent protection
- Yes
- Insulation resistance monitoring
- Yes
- Residual current detection
- Yes
- Built-in PV switch
- Yes
- DC reverse polarity protection
- Yes (PV modules only)
- Ingress protection / overvoltage category
- I / II (PV and BAT), III (MAINS, BACKUP and GEN)
- Built-in AFCI 2.0 module
- Optional
- Anti-islanding protection
- Yes
General data
- Dimensions (W × H × D)
- 335 × 560 × 253 mm
- Weight
- 23 kg
- Weight
- 23 kg
- Weight
- 23 kg
- Weight
- 23 kg
- Weight
- 23 kg
- Weight
- 23.5 kg
- Weight
- 23.8 kg
- Weight
- 23.8 kg
- Inverter topology
- Non-isolated (PV), isolated (battery)
- Self-consumption
- < 40 W
- Operating temperature range
- -25 ~ +60°C
- Relative humidity
- 0 - 100%
- Ingress protection (IP)
- IP66
- Noise level (typical)
- < 40 dB(A)
- Noise level (typical)
- < 40 dB(A)
- Noise level (typical)
- < 40 dB(A)
- Noise level (typical)
- < 40 dB(A)
- Noise level (typical)
- < 40 dB(A)
- Noise level (typical)
- < 65 dB(A)
- Noise level (typical)
- < 65 dB(A)
- Noise level (typical)
- < 65 dB(A)
- Cooling method
- Natural cooling
- Max. operating altitude
- 3000 m
Grid connection standard
- Safety / EMC standard
- IEC/EN 62109-1/-2, EN 61000-6-2/-3
Features
- PV connection
- MC4 connector
- Battery connection
- Terminal block
- AC connection
- Terminal block
- Display
- 7.0" LCD display and Bluetooth + app
- Communication interface
- RS485-Meter, RS485, DRM, DI, DO×2; optional: 4G
Documentation and certificates
-
DownloadDatasheet
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний.pdf
-
DownloadDatasheet
S6-EH1P(3-10)K-Flyer-V4.0_20260528140034.pdf
-
DownloadUser manual
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_інструкція1.pdf
-
DownloadCertificate 1
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат1.pdf
-
DownloadCertificate 2
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат2.pdf
-
DownloadCertificate 3
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат3.pdf
-
DownloadCertificate 4
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат4.pdf
-
DownloadCertificate 5
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат5.pdf
-
DownloadCertificate 6
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат6.pdf
-
DownloadCertificate 7
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат7.pdf
-
DownloadCertificate 8
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат8.pdf
-
DownloadCertificate 9
Гібридний інвертор Solis S6-EH1P (3–10) кВт · однофазний · низьковольтний_сертифікат9.pdf
Frequently asked questions
-
Start from the site's average daily consumption and the peak load the inverter has to carry in off-grid mode. The power range of each modification and the recommended PV array size for it are listed in the product card under "Key specifications" — for a precise selection, contact a Solis dealer or use the form below.
-
The list of validated batteries is published on the product page — in the compatible-equipment section, where one has already been compiled for that model. The voltage range (LV or HV, depending on the series) is stated in the technical specifications either way. If there is no list, or the battery you need is not on it, contact the Solis Ukraine technical department — compatibility should be confirmed separately.
-
Most Solis hybrid and off-grid inverters support connecting a generator with automatic start-up when the battery is discharged. Whether a specific model has this function, and how it is wired, is stated under "Key features" and in the "Technical specifications" table of the product card.
-
It depends on the series: single-phase models are designed for a 220 V grid, three-phase models for 380/400 V. The exact connection type for a given product is stated in the "Grid phases" card under "Key specifications".
-
Solis equipment carries the manufacturer's warranty, which in Ukraine is administered by official dealers and authorised service centres. The exact term and conditions are stated on the warranty card and on the device's rating plate — for registration and the claim procedure, see the Support section.
Didn't find your answer?
The Solis Ukraine technical department advises on equipment compatibility, wiring diagrams and system configuration.