Single-phase grid-tied
Solis S6-GR1P grid-tied inverter (0.7–3.6) kW · single-phase
Solis S6-GR1P (0.7–3.6 kW) is a compact and silent single-phase grid-tied inverter from the S6 series, designed for residential solar power plants operating for self-consumption or under a feed-in tariff. It offers a high efficiency of up to 97.7%, an ultra-low start-up voltage from 60 V and built-in intelligent arc-fault protection (AFCI).
Models
1 / 5
1 / 5
Overview
Solis S6-GR1P (0.7–3.6 kW) is a compact single-phase grid-tied inverter for micro solar power plants running on self-consumption or the feed-in tariff. It is ideal for flats, holiday homes, private houses and small businesses with a basic daytime load.
The model operates without batteries, feeding the solar energy it generates directly to your appliances. This dramatically cuts daytime electricity bills and delivers the fastest payback, since there is no battery expenditure.
The inverter supports an input current of up to 14 A, making it fully compatible with modern high-power PV modules. Thanks to its low start-up voltage, the unit switches on earlier and runs longer through the day, extracting the maximum number of kilowatt-hours from every ray of sunlight.
With fanless passive cooling, the inverter runs completely silently and installs easily even in living areas. The unit features arc-fault protection (AFCI), supports Wi-Fi monitoring and offers grid export limitation.
Key specifications
-
Power range (kW)
0.7–3.6
-
Grid phases
Single-phase (220 V)
-
Number of MPPT trackers
1 MPPT
-
Energy system type
Grid export / feed-in tariff
Key features
-
Maximum efficiency 97.3%
-
Wide voltage range and low start-up voltage
-
Supports output power control
-
AFCI protection actively reduces the risk of fire
-
24-hour monitoring of consumed load
-
Adapted to weak grids Models: S6-GR1P0.7K-M / S6-GR1P1K-M S6-GR1P1.5K-M / S6-GR1P2K-M S6-GR1P2.5K-M / S6-GR1P3K-M S6-GR1P3.6K-M 360 degrees
Technical specifications
Models
SKU: S6-GR1P0.7K-M
DC input
- Recommended maximum input power
- 1.1 kW
- Recommended maximum input power
- 1.5 kW
- Recommended maximum input power
- 2.3 kW
- Recommended maximum input power
- 3 kW
- Recommended maximum input power
- 3.8 kW
- Recommended maximum input power
- 4.5 kW
- Recommended maximum input power
- 5.4 kW
- Maximum input voltage
- 600 V
- Rated voltage
- 200 V
- Rated voltage
- 200 V
- Rated voltage
- 200 V
- Rated voltage
- 330 V
- Rated voltage
- 330 V
- Rated voltage
- 330 V
- Rated voltage
- 330 V
- Start-up voltage
- 60 V
- Start-up voltage
- 60 V
- Start-up voltage
- 60 V
- Start-up voltage
- 90 V
- Start-up voltage
- 90 V
- Start-up voltage
- 90 V
- Start-up voltage
- 90 V
- MPPT voltage range
- 50 - 500 V
- MPPT voltage range
- 50 - 500 V
- MPPT voltage range
- 50 - 500 V
- MPPT voltage range
- 80 - 500 V
- MPPT voltage range
- 80 - 500 V
- MPPT voltage range
- 80 - 500 V
- MPPT voltage range
- 80 - 500 V
- Max. input current
- 14 A
- Max. input current
- 14 A
- Max. input current
- 14 A
- Max. input current
- 14 A
- Max. input current
- 14 A
- Max. input current
- 14 A
- Max. input current
- 19 A
- Max. short-circuit current
- 22 A
- Max. short-circuit current
- 22 A
- Max. short-circuit current
- 22 A
- Max. short-circuit current
- 22 A
- Max. short-circuit current
- 22 A
- Max. short-circuit current
- 22 A
- Max. short-circuit current
- 24 A
- Number of MPPTs / max. inputs per MPPT
- 1 / 1
- Number of MPPTs / max. inputs per MPPT
- 1 / 1
- Number of MPPTs / max. inputs per MPPT
- 1 / 1
- Number of MPPTs / max. inputs per MPPT
- 1 / 1
- Number of MPPTs / max. inputs per MPPT
- 1 / 1
- Number of MPPTs / max. inputs per MPPT
- 1 / 1
- Number of MPPTs / max. inputs per MPPT
- 1 / 2
AC output
- Rated output power
- 0.7 kW
- Rated output power
- 1 kW
- Rated output power
- 1.5 kW
- Rated output power
- 2 kW
- Rated output power
- 2.5 kW
- Rated output power
- 3 kW
- Rated output power
- 3.6 kW
- Max. apparent output power
- 0.77 kVA
- Max. apparent output power
- 1.1 kVA
- Max. apparent output power
- 1.65 kVA
- Max. apparent output power
- 2.2 kVA
- Max. apparent output power
- 2.75 kVA
- Max. apparent output power
- 3.3 kVA
- Max. apparent output power
- 3.6 kVA
- Rated grid voltage
- 1/N/PE, 220 V / 230 V
- Rated grid frequency
- 50 Hz / 60 Hz
- Rated grid output current
- 3.2 A / 3.0 A
- Rated grid output current
- 4.5 A / 4.3 A
- Rated grid output current
- 6.8 A / 6.5 A
- Rated grid output current
- 9.1 A / 8.7 A
- Rated grid output current
- 11.4 A / 10.9 A
- Rated grid output current
- 13.6 A / 13 A
- Rated grid output current
- 16 A
- Max. output current
- 4.4 A
- Max. output current
- 5.2 A
- Max. output current
- 8.1 A
- Max. output current
- 10.5 A
- Max. output current
- 13.3 A
- Max. output current
- 15.7 A
- Max. output current
- 16 A
- Power factor
- > 0.99 (-0.8 to +0.8)
- THDi
- < 3%
Efficiency
- Maximum efficiency
- 96.6%
- Maximum efficiency
- 96.6%
- Maximum efficiency
- 96.6%
- Maximum efficiency
- 97.1%
- Maximum efficiency
- 97.1%
- Maximum efficiency
- 97.1%
- Maximum efficiency
- 97.3%
- European efficiency
- 95.3%
- European efficiency
- 95.3%
- European efficiency
- 95.4%
- European efficiency
- 96.4%
- European efficiency
- 96.7%
- European efficiency
- 96.7%
- European efficiency
- 96.8%
Protection
- DC reverse polarity protection
- Yes
- Short-circuit protection
- Yes
- Overcurrent protection
- Yes
- Surge protection
- Yes
- Grid monitoring
- Yes
- Anti-islanding protection
- Yes
- Temperature protection
- Yes
- Multi-peak scanning
- Yes
- Built-in AFCI module
- Yes
- Built-in DC disconnector
- Yes
General data
- Dimensions (W × H × D)
- 310 × 373 × 160 mm
- Weight
- 7.4 kg
- Weight
- 7.4 kg
- Weight
- 7.4 kg
- Weight
- 7.4 kg
- Weight
- 7.7 kg
- Weight
- 7.7 kg
- Weight
- 7.7 kg
- Inverter topology
- Transformerless
- Self-consumption
- < 1 W
- Ambient operating temperature range
- -25 ~ +60°C
- Relative humidity
- 0 - 100%
- Ingress protection (IP)
- IP66
- Noise level (typical)
- < 20 dB(A)
- Cooling method
- Natural cooling
- Max. operating altitude
- 4000 m
- Grid connection standard
- UNE 206006/UNE 206007-1, CEI 0-21, C10/11, TOR, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727,
- Safety / EMC standard
- IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
Features
- DC connection
- MC4 connector
- AC connection
- Quick-connect connector
- Display
- LCD screen
- Communication
- RS485, optional: Wi-Fi, GPRS
Documentation and certificates
-
DownloadDatasheet
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний.pdf
-
DownloadUser manual
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_інструкція.pdf
-
DownloadCertificate 1
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат1.pdf
-
DownloadCertificate 2
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат2.pdf
-
DownloadCertificate 3
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат3.pdf
-
DownloadCertificate 4
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат4.pdf
-
DownloadCertificate 5
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат5.pdf
-
DownloadCertificate 6
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат6.pdf
-
DownloadCertificate 7
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат7.pdf
-
DownloadCertificate 8
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат8.pdf
-
DownloadCertificate 9
Мережевий інвертор Solis S6-GR1P (0,7–3,6) кВт · однофазний_сертифікат9.pdf
Frequently asked questions
-
Start from the site's average daily consumption and the peak load the inverter has to carry in off-grid mode. The power range of each modification and the recommended PV array size for it are listed in the product card under "Key specifications" — for a precise selection, contact a Solis dealer or use the form below.
-
The list of validated batteries is published on the product page — in the compatible-equipment section, where one has already been compiled for that model. The voltage range (LV or HV, depending on the series) is stated in the technical specifications either way. If there is no list, or the battery you need is not on it, contact the Solis Ukraine technical department — compatibility should be confirmed separately.
-
Most Solis hybrid and off-grid inverters support connecting a generator with automatic start-up when the battery is discharged. Whether a specific model has this function, and how it is wired, is stated under "Key features" and in the "Technical specifications" table of the product card.
-
It depends on the series: single-phase models are designed for a 220 V grid, three-phase models for 380/400 V. The exact connection type for a given product is stated in the "Grid phases" card under "Key specifications".
-
Solis equipment carries the manufacturer's warranty, which in Ukraine is administered by official dealers and authorised service centres. The exact term and conditions are stated on the warranty card and on the device's rating plate — for registration and the claim procedure, see the Support section.
Didn't find your answer?
The Solis Ukraine technical department advises on equipment compatibility, wiring diagrams and system configuration.