Hybrid inverters for C&I
Solis S6-EH3P hybrid inverter (80–125) kW · three-phase · high voltage
Solis S6-EH3P (80–125 kW) is an ultra-high-power three-phase high-voltage hybrid inverter for large enterprises, factories and commercial complexes. It works with high-voltage batteries (150–800 V), features up to 8–10 MPPT trackers, delivers instant backup power (UPS <10 ms) and scales to 6 units in a single system.
Models
1 / 4
1 / 4
Overview
Solis S6-EH3P (80–125 kW) is the flagship megawatt-class three-phase high-voltage hybrid inverter for large industrial sites and the C&I sector. The series is intended for large plants, factories, logistics hubs, grain elevators, data centres and hypermarkets with critical power-continuity requirements. The inverter works with powerful high-voltage (HV) battery systems. The high battery bus voltage minimises resistive losses in the cabling, guarantees maximum efficiency and delivers high charge/discharge currents for rapid energy capture during short windows of grid availability or from diesel generators.
The model is built for large-scale PV arrays: 10 independent MPPT trackers with high input current support allow a large number of module strings to be connected on complex roofs or ground-mounted structures using modern bifacial PV modules. A 10 ms transfer to off-grid supply protects sensitive industrial equipment from disruption, while the high overload capability ensures confident start-up of powerful motors, compressors and pumps.
Solis S6-EH3P (80–125)K10 supports extended parallel operation of multiple units, full compatibility with industrial diesel generator sets, Zero Export and peak shaving, plus dynamic reactive power compensation.
Key specifications
-
Power range (kW)
80–125
-
Grid phases
Three-phase (380 V)
-
Number of MPPT trackers
6+ MPPT
-
Built-in monitoring
Wi-Fi, LAN, 4G
Key features
-
Supports up to twice the rated PV input current, making the most of the available solar energy
-
Supports a maximum string input current of 21 A, ensuring compatibility with high-power PV modules
-
Compatible with 100-314 Ah battery modules, reducing overall system costs
-
Supports fast battery charging with a maximum charge current of 200 A
-
Two independent battery ports for flexible configuration and easy capacity expansion
-
Delivers 160% overload for 200 ms in off-grid mode, ensuring reliable start-up of heavy loads
-
Enables flexible control in weak-grid conditions and with hybrid generator sets, reducing capital expenditure
-
AI integration and VPP readiness enable dynamic tariff optimisation, minimising electricity costs and opening up additional revenue streams
-
Integrates PV modules and storage for demand management and anti-backflow functions
-
Provides dynamic reactive power compensation to enhance grid power factor and lower reactive power charges
Technical specifications
Models
SKU: S6-EH3P75K10-NV-YD-H
DC input (PV side)
- Recommended max. PV array size
- 150 kW
- Recommended max. PV array size
- 160 kW
- Recommended max. PV array size
- 200 kW
- Recommended max. PV array size
- 250 kW
- Max. usable PV module input power
- 150 kW
- Max. usable PV module input power
- 160 kW
- Max. usable PV module input power
- 200 kW
- Max. usable PV module input power
- 250 kW
- Maximum input voltage
- 1000 V
- Rated voltage
- 600 V
- Start-up voltage
- 180 V
- MPPT voltage range
- 150 - 950 V
- Max. input current
- 10 × 42 A
- Max. current at the DC input
- 42 A
- Max. short-circuit current
- 10 × 60 A
- Number of MPPTs / max. inputs per MPPT
- 10 / 20
Battery
- Battery type
- Lithium-ion
- Battery voltage range
- 300 - 950 V
- Maximum charge / discharge current
- 100 A × 2 / 100 A × 2
- Number of battery ports / BMS ports
- 2
- Maximum charge / discharge current of each port
- 100 A
- Communication
- CAN
AC output (grid side)
- Rated output power
- 75 kW
- Rated output power
- 80 kW
- Rated output power
- 100 kW
- Rated output power
- 125 kW
- Max. apparent output power
- 75 kVA
- Max. apparent output power
- 80 kVA
- Max. apparent output power
- 100 kVA
- Max. apparent output power
- 125 kVA
- Rated grid voltage
- 3/N/PE, 220 V / 380 V, 230 V / 400 V
- Rated grid frequency
- 50 Hz / 60 Hz
- Rated grid output current
- 114 A
- Rated grid output current
- 121.6 A / 115.5 A
- Rated grid output current
- 151.9 A / 144.3 A
- Rated grid output current
- 189.9 A / 180.4 A
- Power factor
- > 0.99 (-0.8 to +0.8)
- THDi
- < 3%
AC input (grid side)
- Max. input power
- 150 kW
- Max. input power
- 160 kW
- Max. input power
- 164.5 kW / 173.2 kW
- Max. input power
- 164.5 kW / 173.2 kW
- Input voltage range
- 304 - 460 V
- Max. input current
- 250 A
AC output (backup output)
- Rated output power
- 75 kW
- Rated output power
- 80 kW
- Rated output power
- 100 kW
- Rated output power
- 125 kW
- Max. apparent output power
- 125K: 1.4× rated power, 10 s; 1.6× rated power, 200 ms
- Backup switchover time
- < 10 ms
- Rated output voltage
- 3/N/PE, 220 V / 380 V, 230 V / 400 V
- Rated frequency
- 50 Hz / 60 Hz
- Rated output current
- 114.0 A
- Rated output current
- 121.6 A / 115.5 A
- Rated output current
- 151.9 A / 144.3 A
- Rated output current
- 189.9 A / 180.4 A
- Max. AC pass-through current
- 114.0 A
- Max. AC pass-through current
- 121.6 A / 115.5 A
- Max. AC pass-through current
- 151.9 A / 144.3 A
- Max. AC pass-through current
- 189.9 A / 180.4 A
- THDv (at linear load)
- < 3%
AC input (generator side)
- Max. input power
- 75 kW
- Max. input power
- 80 kW
- Max. input power
- 100 kW
- Max. input power
- 125 kW
- Rated input current
- 114.0 A
- Rated input current
- 121.6 A / 115.5 A
- Rated input current
- 151.9 A / 144.3 A
- Rated input current
- 189.9 A / 180.4 A
- Rated input voltage
- 3/N/PE, 220 V / 380 V, 230 V / 400 V
- Rated input frequency
- 50 Hz / 60 Hz
Efficiency
- Maximum efficiency
- 97.5%
- European efficiency
- 96.9%
- European efficiency
- 96.9%
- European efficiency
- 97.1%
- European efficiency
- 97.2%
- Max. battery charging efficiency from PV / AC
- 98.2% /97.0%
- Battery discharge efficiency
- 97.0%
Protection
- Surge protection
- DC type II / AC type II
- Overcurrent protection
- Yes
- Insulation resistance monitoring
- Yes
- Residual current detection
- Yes
- Built-in PV switch
- Yes
- DC reverse polarity protection
- Yes
- Ingress protection / overvoltage category
- I/ DC II, AC III
- Built-in AFCI 2.0 module
- Optional
- Anti-islanding protection
- Yes
General data
- Maximum power per phase (grid and backup)
- 33% of rated power
- Dimensions (W × H × D)
- 1174 × 814 × 400 mm
- Weight
- 170 kg
- Inverter topology
- Non-isolated
- Self-consumption
- < 45 W
- Operating temperature range
- -25 ~ +60°C
- Relative humidity
- 0 - 100%
- Ingress protection (IP)
- IP66
- Cooling method
- Fan with intelligent speed control
- Max. operating altitude
- 3000 m
Grid connection standard
- Safety / EMC standard
- IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011
Features
- PV connection
- MC4 connector
- Battery connection
- Terminal connectors
- AC connection
- Terminal block
- Display
- 7.0" LCD display and Bluetooth + app
- Communication interface
- Standard: Wi-Fi+LAN+Bluetooth, CAN-BMS×2, CAN-Parallel×2, LAN, RS485-Meter, RS485, DRM, DI×5, DO×4; optional: 4G
Documentation and certificates
-
DownloadDatasheet
Гібридний інвертор Solis S6-EH3P (80–125) кВт · трифазний · високовольтний.pdf
-
DownloadDatasheet
S6-EH3P(75-125)K-Global-Flyer-V4.2_20260819145345.pdf
-
DownloadUser manual
Гібридний інвертор Solis S6-EH3P (80–125) кВт · трифазний · високовольтний_інструкція.pdf
-
DownloadCertificate 1
Гібридний інвертор Solis S6-EH3P (80–125) кВт · трифазний · високовольтний_сертифікат1.pdf
-
DownloadCertificate 2
Гібридний інвертор Solis S6-EH3P (80–125) кВт · трифазний · високовольтний_сертифікат2.pdf
-
DownloadCertificate 3
Гібридний інвертор Solis S6-EH3P (80–125) кВт · трифазний · високовольтний_сертифікат3.pdf
-
DownloadCertificate 4
Гібридний інвертор Solis S6-EH3P (80–125) кВт · трифазний · високовольтний_сертифікат4.pdf
-
DownloadCertificate 5
Гібридний інвертор Solis S6-EH3P (80–125) кВт · трифазний · високовольтний_сертифікат5.pdf
Frequently asked questions
-
Start from the site's average daily consumption and the peak load the inverter has to carry in off-grid mode. The power range of each modification and the recommended PV array size for it are listed in the product card under "Key specifications" — for a precise selection, contact a Solis dealer or use the form below.
-
The list of validated batteries is published on the product page — in the compatible-equipment section, where one has already been compiled for that model. The voltage range (LV or HV, depending on the series) is stated in the technical specifications either way. If there is no list, or the battery you need is not on it, contact the Solis Ukraine technical department — compatibility should be confirmed separately.
-
Most Solis hybrid and off-grid inverters support connecting a generator with automatic start-up when the battery is discharged. Whether a specific model has this function, and how it is wired, is stated under "Key features" and in the "Technical specifications" table of the product card.
-
It depends on the series: single-phase models are designed for a 220 V grid, three-phase models for 380/400 V. The exact connection type for a given product is stated in the "Grid phases" card under "Key specifications".
-
Solis equipment carries the manufacturer's warranty, which in Ukraine is administered by official dealers and authorised service centres. The exact term and conditions are stated on the warranty card and on the device's rating plate — for registration and the claim procedure, see the Support section.
Didn't find your answer?
The Solis Ukraine technical department advises on equipment compatibility, wiring diagrams and system configuration.