C&I
Solis FlexCore-ID energy storage system 60–261 kWh · indoor
Solis FlexCore-ID (60–261 kWh) is a modular stackable energy storage system (C&I ESS) for indoor installation that works with hybrid inverters from 15 to 125 kW. It is designed for commercial and industrial facilities, with easy vertical assembly and capacity scaling up to 1500 kWh.
Models
1 / 4
1 / 4
Overview
Solis FlexCore-ID (60–261 kWh) is a highly efficient modular energy storage system (Commercial & Industrial ESS) developed specifically for indoor installation in the C&I sector. It is the optimal choice for enterprises, production facilities, business centres, warehouse complexes and sites with critical power-continuity requirements.
The key advantage of FlexCore-ID is its lightweight stackable battery PACK design with Plug-and-Play technology. Each 20 kWh module weighs just 151 kg, so the equipment can easily be moved through narrow doorways and corridors without heavy lifting machinery or a complex foundation. Within a single cluster, capacity scales flexibly from 60 to 261 kWh, and with up to 6 clusters connected in parallel the total energy reserve extends to 1560 kWh.
The system is built on safe LiFePO₄ cells (314 Ah, Grade A+) rated for over 8,000 cycles. The model features a 5-level fire safety system (including aerosol fire suppression and ceramic-mica insulation), supports seamless switchover to backup power (< 10 ms), handles 200% PV oversizing, and offers Peak Shaving and Zero Export functions along with smart management via Solis AI and SolisCloud.
Key specifications
-
Battery voltage
High voltage — HV (200 V+)
Key features
-
Modular stackable indoor design with lightweight packs (151 kg) for easy transport through narrow passageways
-
Premium LiFePO₄ battery cells (314 Ah, Grade A+) with an extended service life of over 8,000 cycles
-
Scalable from 60 to 261 kWh per cluster, with up to 6 clusters in parallel (up to 1560 kWh)
-
Plug-and-play connection with no foundation required, plus built-in dual DC outputs that eliminate the need for an external combiner cabinet
-
5-level fire and thermal safety system (aerosol suppression module, ceramic and mica insulation, directed venting channels)
-
Instant transfer to backup power (< 10 ms) with support for 160% short-term overload in off-grid mode
-
Support for 200% PV array oversizing and string currents up to 21 A for maximum compatibility with high-power PV modules
-
Intelligent control via Solis AI and SolisCloud with a 7" colour LCD display, Bluetooth and OTA update support
Technical specifications
Models
SKU: FlexCore Indoor Stackable Series S6-EH3P 30K-H(21A)
DC input (PV side)
- Recommended max. PV array size
- 60 kW
- Recommended max. PV array size
- 80 kW
- Recommended max. PV array size
- 100 kW
- Recommended max. PV array size
- 100 kW
- Recommended max. PV array size
- 160 kW
- Recommended max. PV array size
- 200 kW
- Recommended max. PV array size
- 250 kW
- Max. usable PV module input power
- 60 kW
- Max. usable PV module input power
- 80 kW
- Max. usable PV module input power
- 100 kW
- Max. usable PV module input power
- 100 kW
- Max. usable PV module input power
- 160 kW
- Max. usable PV module input power
- 200 kW
- Max. usable PV module input power
- 250 kW
- Maximum input voltage
- 1000 V
- Rated voltage
- 600 V
- Start-up voltage
- 180 V
- MPPT voltage range
- 150 - 850 V
- MPPT voltage range
- 150 - 850 V
- MPPT voltage range
- 150 - 850 V
- MPPT voltage range
- 150 - 850 V
- MPPT voltage range
- 150 - 950 V
- MPPT voltage range
- 150 - 950 V
- MPPT voltage range
- 150 - 950 V
- Max. input current
- 3 × 42 A
- Max. input current
- 4 × 42 A
- Max. input current
- 4 × 42 A
- Max. input current
- 4 × 42 A
- Max. input current
- 10 × 42 A
- Max. input current
- 10 × 42 A
- Max. input current
- 10 × 42 A
- Max. current at the DC input
- 42 A
- Max. short-circuit current
- 3 × 60 A
- Max. short-circuit current
- 4 × 60 A
- Max. short-circuit current
- 4 × 60 A
- Max. short-circuit current
- 4 × 60 A
- Max. short-circuit current
- 10 × 60 A
- Max. short-circuit current
- 10 × 60 A
- Max. short-circuit current
- 10 × 60 A
- Number of MPPTs / max. inputs per MPPT
- 3 / 6
- Number of MPPTs / max. inputs per MPPT
- 4 / 8
- Number of MPPTs / max. inputs per MPPT
- 4 / 8
- Number of MPPTs / max. inputs per MPPT
- 4 / 8
- Number of MPPTs / max. inputs per MPPT
- 10 / 20
- Number of MPPTs / max. inputs per MPPT
- 10 / 20
- Number of MPPTs / max. inputs per MPPT
- 10 / 20
Battery
- Battery type
- Lithium-ion
- Battery voltage range
- 150 - 800 V
- Battery voltage range
- 150 - 800 V
- Battery voltage range
- 150 - 800 V
- Battery voltage range
- 150 - 800 V
- Battery voltage range
- 300 - 950 V
- Battery voltage range
- 300 - 950 V
- Battery voltage range
- 300 - 950 V
- Maximum charge / discharge current
- 80 A × 2 / 80 A × 2
- Maximum charge / discharge current
- 80 A × 2 / 80 A × 2
- Maximum charge / discharge current
- 80 A × 2 / 80 A × 2
- Maximum charge / discharge current
- 84 A × 2 / 84 A × 2
- Maximum charge / discharge current
- 100 A × 2 / 100 A × 2
- Maximum charge / discharge current
- 100 A × 2 / 100 A × 2
- Maximum charge / discharge current
- 100 A × 2 / 100 A × 2
- Number of battery ports / BMS ports
- 2
- Max. charge / discharge current per port
- 80 A
- Max. charge / discharge current per port
- 80 A
- Max. charge / discharge current per port
- 80 A
- Max. charge / discharge current per port
- 84 A
- Max. charge / discharge current per port
- 100 A
- Max. charge / discharge current per port
- 100 A
- Max. charge / discharge current per port
- 100 A
- Communication
- CAN / RS485
AC output (grid side)
- Rated output power
- 30 kW
- Rated output power
- 40 kW
- Rated output power
- 50 kW
- Rated output power
- 60 kW
- Rated output power
- 80 kW
- Rated output power
- 100 kW
- Rated output power
- 125 kW
- Max. apparent output power
- 30 kVA
- Max. apparent output power
- 40 kVA
- Max. apparent output power
- 50 kVA
- Max. apparent output power
- 60 kVA
- Max. apparent output power
- 80 kVA
- Max. apparent output power
- 100 kVA
- Max. apparent output power
- 125 kVA
- Rated grid voltage
- 3/N/PE, 220 V / 380 V, 230 V / 400 V
- Rated grid frequency
- 50 Hz / 60 Hz
- Rated grid output current
- 45.6 A / 43.3 A
- Rated grid output current
- 60.8 A / 57.7 A
- Rated grid output current
- 76 A / 72.2 A
- Rated grid output current
- 91.2 A / 86.6 A
- Rated grid output current
- 121.6 A / 115.5 A
- Rated grid output current
- 151.9 A / 144.3 A
- Rated grid output current
- 189.9 A / 180.4 A
- Power factor
- > 0.99 (0.8 leading - 0.8 lagging)
- THDi
- < 3%
AC input (grid side)
- Max. input power
- 60 kW
- Max. input power
- 60 kW
- Max. input power
- 100 kW
- Max. input power
- 100 kW / 105 kW
- Max. input power
- 160 kW
- Max. input power
- 164.5 kW / 173.2 kW
- Max. input power
- 164.5 kW / 173.2 kW
- Input voltage range
- 304 - 460 V
- Max. input current
- 91.2 A / 86.6 A
- Max. input current
- 121.6 A / 115.4 A 152 A / 144.4 A
- Max. input current
- 121.6 A / 115.4 A 152 A / 144.4 A
- Max. input current
- 152 A / 152 A
- Max. input current
- 250 A
- Max. input current
- 250 A
- Max. input current
- 250 A
AC output (backup output)
- Rated output power
- 30 kW
- Rated output power
- 40 kW
- Rated output power
- 50 kW
- Rated output power
- 60 kW
- Rated output power
- 80 kW
- Rated output power
- 100 kW
- Rated output power
- 125 kW
- Max. apparent output power
- 80-100K: 1.6 times of rated power, 10 s; 2 times of rated power, 200 ms;
- Backup switchover time
- < 10 ms
- Rated output voltage
- 3/N/PE, 220 V / 380 V, 230 V / 400 V
- Rated frequency
- 50 Hz / 60 Hz
- Rated output current
- 45.6 A / 43.3 A
- Rated output current
- 60.8 A / 57.7 A
- Rated output current
- 76 A / 72.2 A
- Rated output current
- 91.2 A / 86.6 A
- Rated output current
- 121.6 A / 115.5 A
- Rated output current
- 151.9 A / 144.3 A
- Rated output current
- 189.9 A / 180.4 A
- Max. AC pass-through current
- 45.6 A / 43.3 A
- Max. AC pass-through current
- 60.8 A / 57.7 A
- Max. AC pass-through current
- 76 A / 72.2 A
- Max. AC pass-through current
- 91.2 A / 86.6 A
- Max. AC pass-through current
- 121.6 A / 115.5 A
- Max. AC pass-through current
- 151.9 A / 144.3 A
- Max. AC pass-through current
- 189.9 A / 180.4 A
- THDv (at linear load)
- < 2%
- THDv (at linear load)
- < 2%
- THDv (at linear load)
- < 2%
- THDv (at linear load)
- < 2%
- THDv (at linear load)
- < 3%
- THDv (at linear load)
- < 3%
- THDv (at linear load)
- < 3%
AC input (generator side)
- Max. input power
- 30 kW
- Max. input power
- 40 kW
- Max. input power
- 50 kW
- Max. input power
- 60 kW
- Max. input power
- 80 kW
- Max. input power
- 100 kW
- Max. input power
- 125 kW
- Rated input current
- 45.6 A / 43.3 A
- Rated input current
- 60.8 A / 57.7 A
- Rated input current
- 76 A / 72.2 A
- Rated input current
- 91.2 A / 86.6 A
- Rated input current
- 121.6 A / 115.5 A
- Rated input current
- 151.9 A / 144.3 A
- Rated input current
- 189.9 A / 180.4 A
- Rated input voltage
- 3/N/PE, 220 V / 380 V, 230 V / 400 V
- Rated input frequency
- 50 Hz / 60 Hz
Efficiency
- Maximum efficiency
- 97.7%
- Maximum efficiency
- 97.7%
- Maximum efficiency
- 97.7%
- Maximum efficiency
- 97.7%
- Maximum efficiency
- 97.5%
- Maximum efficiency
- 97.5%
- Maximum efficiency
- 97.5%
- European efficiency
- 97.3%
- European efficiency
- 97.3%
- European efficiency
- 97.3%
- European efficiency
- 97.3%
- European efficiency
- 96.9%
- European efficiency
- 97.1%
- European efficiency
- 97.2%
- Max. battery charging efficiency from PV / AC
- 98.5% / 97.8%
- Max. battery charging efficiency from PV / AC
- 98.5% / 97.8%
- Max. battery charging efficiency from PV / AC
- 98.5% / 97.8%
- Max. battery charging efficiency from PV / AC
- 98.5% / 97.8%
- Max. battery charging efficiency from PV / AC
- 98.2% /97.0%
- Max. battery charging efficiency from PV / AC
- 98.2% /97.0%
- Max. battery charging efficiency from PV / AC
- 98.2% /97.0%
- Battery discharge efficiency
- 97.5%
- Battery discharge efficiency
- 97.5%
- Battery discharge efficiency
- 97.5%
- Battery discharge efficiency
- 97.5%
- Battery discharge efficiency
- 97.0%
- Battery discharge efficiency
- 97.0%
- Battery discharge efficiency
- 97.0%
General data
- Max. power per phase (grid and backup)
- 33% rated power
- Dimensions (W × H × D)
- 530 × 880 × 290 mm
- Dimensions (W × H × D)
- 530 × 880 × 290 mm
- Dimensions (W × H × D)
- 530 × 880 × 290 mm
- Dimensions (W × H × D)
- 530 × 880 × 290 mm
- Dimensions (W × H × D)
- 1174 × 814 × 400 mm
- Dimensions (W × H × D)
- 1174 × 814 × 400 mm
- Dimensions (W × H × D)
- 1174 × 814 × 400 mm
- Weight
- 76 kg
- Weight
- 76 kg
- Weight
- 76 kg
- Weight
- 76 kg
- Weight
- 170 kg
- Weight
- 170 kg
- Weight
- 170 kg
- Inverter topology
- Transformerless
- Self-consumption
- < 35 W
- Self-consumption
- < 35 W
- Self-consumption
- < 35 W
- Self-consumption
- < 35 W
- Self-consumption
- < 45 W
- Self-consumption
- < 45 W
- Self-consumption
- < 45 W
- Operating temperature range
- -25 ~ +60°C
- Relative humidity
- 0 - 100%
- Ingress protection (IP)
- IP66
- Cooling method
- Intelligent redundant fan cooling
- Max. operating altitude
- 4000 m
- Max. operating altitude
- 4000 m
- Max. operating altitude
- 4000 m
- Max. operating altitude
- 4000 m
- Max. operating altitude
- 3000 m
- Max. operating altitude
- 3000 m
- Max. operating altitude
- 3000 m
Grid connection standard
- Safety / EMC standard
- IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011
Documentation and certificates
-
DownloadDatasheet
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень.pdf
-
DownloadUser manual
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень_інструкція.pdf
-
DownloadCertificate 1
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень_сертифікат.pdf
-
DownloadCertificate 2
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень_сертифікат2.pdf
-
DownloadCertificate 3
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень_сертифікат3.pdf
-
DownloadCertificate 4
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень_сертифікат4.pdf
-
DownloadCertificate 5
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень_сертифікат5.pdf
-
DownloadCertificate 6
Система накопичення Solis FlexCore-ID 60–261 кВт·год · для приміщень_сертифікат6.pdf
Frequently asked questions
-
Start from the site's average daily consumption and the peak load the inverter has to carry in off-grid mode. The power range of each modification and the recommended PV array size for it are listed in the product card under "Key specifications" — for a precise selection, contact a Solis dealer or use the form below.
-
The list of validated batteries is published on the product page — in the compatible-equipment section, where one has already been compiled for that model. The voltage range (LV or HV, depending on the series) is stated in the technical specifications either way. If there is no list, or the battery you need is not on it, contact the Solis Ukraine technical department — compatibility should be confirmed separately.
-
Most Solis hybrid and off-grid inverters support connecting a generator with automatic start-up when the battery is discharged. Whether a specific model has this function, and how it is wired, is stated under "Key features" and in the "Technical specifications" table of the product card.
-
It depends on the series: single-phase models are designed for a 220 V grid, three-phase models for 380/400 V. The exact connection type for a given product is stated in the "Grid phases" card under "Key specifications".
-
Solis equipment carries the manufacturer's warranty, which in Ukraine is administered by official dealers and authorised service centres. The exact term and conditions are stated on the warranty card and on the device's rating plate — for registration and the claim procedure, see the Support section.
Didn't find your answer?
The Solis Ukraine technical department advises on equipment compatibility, wiring diagrams and system configuration.