Residential
Solis FlexAIO S7-EH3P all-in-one system (5–20) kW · 6–54 kWh · three-phase
Solis FlexAIO S7-EH3P (5–20 kW, 6–54 kWh) is a high-performance three-phase all-in-one system that integrates a three-phase hybrid inverter with scalable battery storage. It is designed for building powerful off-grid or backup energy systems in large private homes, country residences, offices and small and medium-sized business facilities.
Models
1 / 4
1 / 4
Overview
Solis FlexAIO S7-EH3P (5–20 kW) is the flagship three-phase All-in-One energy storage and management system, pairing a powerful three-phase hybrid inverter with a modular battery of 6 to 54 kWh. The model is built for uncompromising backup power and self-consumption optimisation at sites with a three-phase supply.
Thanks to a well-considered all-in-one design with "Plug & Play" connections, the system installs quickly and neatly, with no bulky external cable runs between the inverter and the battery packs. The storage unit is built around exceptionally safe LiFePO₄ (lithium iron phosphate) cells with a service life of over 6000 cycles, while the integrated multi-level BMS controller continuously monitors the safety and balance of every module.
The inverter unit withstands significant inrush overloads to confidently start three-phase equipment (pumps, compressors, ventilation and climate-control systems) and guarantees switchover to backup in under 10 ms. The model works with modern high-power PV modules, integrates fully with diesel gensets, supports Peak Shaving and Zero Export, and offers smart management through the SolisCloud app.
Key specifications
-
Battery voltage
High voltage — HV (200 V+)
-
Power range (kW)
5–20
Key features
-
The three-phase All-in-One concept combines a powerful hybrid inverter and battery storage in a single stylish enclosure
-
Fast, cable-free Plug & Play assembly simplifies installation and improves connection reliability
-
Wide capacity scaling from 6 to 54 kWh to suit any site requirement
-
Long-life lithium iron phosphate (LiFePO₄) cells rated for over 6000 cycles with enhanced fire safety
-
Instant transfer to backup mode (< 10 ms) keeps sensitive three-phase equipment and automation running without interruption
-
High overload capability for confident starting of electric motors, compressors and pumping equipment
-
Full support for diesel generators, grid export limiting (Zero Export) and peak shaving
-
Remote control and diagnostics via SolisCloud with over-the-air (OTA) firmware updates
Technical specifications
Models
SKU: FlexAIO S7-EH3P5K03
DC input (PV side)
- Recommended max. PV array size
- 10 kW
- Recommended max. PV array size
- 12 kW
- Recommended max. PV array size
- 16 kW
- Recommended max. PV array size
- 20 kW
- Recommended max. PV array size
- 24 kW
- Recommended max. PV array size
- 30 kW
- Recommended max. PV array size
- 40 kW
- Max. usable PV module input power
- 8 kW
- Max. usable PV module input power
- 9.6 kW
- Max. usable PV module input power
- 12.8 kW
- Max. usable PV module input power
- 16 kW
- Max. usable PV module input power
- 19.2 kW
- Max. usable PV module input power
- 24 kW
- Max. usable PV module input power
- 32 kW
- Maximum input voltage
- 1000 V
- Rated voltage
- 680 V
- Start-up voltage
- 180 V
- MPPT voltage range
- 160 - 950 V
- Max. MPPT input current
- 2 × 21 A
- Max. MPPT short-circuit current
- 2 × 24 A
- Number of MPPTs / max. inputs per MPPT
- 3 / 1 + 1 + 1
- Number of MPPTs / max. inputs per MPPT
- 3 / 1 + 1 + 1
- Number of MPPTs / max. inputs per MPPT
- 3 / 1 + 1 + 1
- Number of MPPTs / max. inputs per MPPT
- 4 / 1 + 1 + 1 + 1
- Number of MPPTs / max. inputs per MPPT
- 4 / 1 + 1 + 1 + 1
- Number of MPPTs / max. inputs per MPPT
- 4 / 1 + 1 + 1 + 1
- Number of MPPTs / max. inputs per MPPT
- 4 / 1 + 1 + 1 + 1
Battery (connection)
- Battery module models
- Solis BAT Series (LiFePO )
- Number of modules per controller
- 1 ~ 6pcs
- Battery module voltage range
- 520 - 812 V
- Maximum charge / discharge power
- 5 kW
- Maximum charge / discharge power
- 6 kW
- Maximum charge / discharge power
- 8 kW
- Maximum charge / discharge power
- 10 kW
- Maximum charge / discharge power
- 12 kW
- Maximum charge / discharge power
- 15 kW
- Maximum charge / discharge power
- 20 kW
- Maximum charge / discharge current
- 9 A
- Maximum charge / discharge current
- 11 A
- Maximum charge / discharge current
- 15 A
- Maximum charge / discharge current
- 19 A
- Maximum charge / discharge current
- 23 A
- Maximum charge / discharge current
- 28 A
- Maximum charge / discharge current
- 38 A
AC output (grid side)
- Rated output power
- 5 kW
- Rated output power
- 6 kW
- Rated output power
- 8 kW
- Rated output power
- 10 kW
- Rated output power
- 12 kW
- Rated output power
- 15 kW
- Rated output power
- 20 kW
- Max. apparent output power
- 5 kVA
- Max. apparent output power
- 6 kVA
- Max. apparent output power
- 8 kVA
- Max. apparent output power
- 10 kVA
- Max. apparent output power
- 12 kVA
- Max. apparent output power
- 15 kVA
- Max. apparent output power
- 20 kVA
- Rated grid voltage
- 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
- Rated grid frequency
- 50 Hz / 60 Hz
- Rated grid output current
- 7.6 A / 7.2 A
- Rated grid output current
- 9 A / 8.6 A
- Rated grid output current
- 12.2 A / 11.5 A
- Rated grid output current
- 15.2 A / 14.4 A
- Rated grid output current
- 18.2 A / 17.3 A
- Rated grid output current
- 22.8 A / 21.7 A
- Rated grid output current
- 30.4 A / 28.8 A
- Power factor
- > 0.99 (0.8 leading - 0.8 lagging)
- THDi
- < 3%
AC input (grid side)
- Max. input power
- 5 kW
- Max. input power
- 6 kW
- Max. input power
- 8 kW
- Max. input power
- 10 kW
- Max. input power
- 12 kW
- Max. input power
- 15 kW
- Max. input power
- 20 kW
- Input voltage range
- 323 - 460 V
- Max. input current
- 15.2 A
- Max. input current
- 18 A
- Max. input current
- 24.4 A
- Max. input current
- 30 A
- Max. input current
- 30 A
- Max. input current
- 45 A
- Max. input current
- 45 A
AC output (backup output)
- Rated output power
- 5 kW
- Rated output power
- 6 kW
- Rated output power
- 8 kW
- Rated output power
- 10 kW
- Rated output power
- 12 kW
- Rated output power
- 15 kW
- Rated output power
- 20 kW
- Max. apparent output power
- 1.5 times of rated power, 10 s
- Backup switchover time
- < 10 ms
- Rated output voltage
- 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
- Rated frequency
- 50 Hz a / 60 Hz
- Rated output current
- 7.6 A / 7.2 A
- Rated output current
- 9 A / 8.6 A
- Rated output current
- 12.2 A / 11.5 A
- Rated output current
- 15.2 A / 14.4 A
- Rated output current
- 18.2 A / 17.3 A
- Rated output current
- 22.8 A / 21.7 A
- Rated output current
- 30.4 A / 28.8 A
- Max. continuous AC pass-through current
- 15.2 A
- Max. continuous AC pass-through current
- 18 A
- Max. continuous AC pass-through current
- 24.4 A
- Max. continuous AC pass-through current
- 30 A
- Max. continuous AC pass-through current
- 30 A
- Max. continuous AC pass-through current
- 45 A
- Max. continuous AC pass-through current
- 45 A
- THDv (at linear load)
- < 3%
AC input (generator side)
- Max. input power
- 5 kW
- Max. input power
- 6 kW
- Max. input power
- 8 kW
- Max. input power
- 10 kW
- Max. input power
- 12 kW
- Max. input power
- 15 kW
- Max. input power
- 20 kW
- Max. input current
- 7.6 A / 7.2 A
- Max. input current
- l 9 A / 8.6 A
- Max. input current
- 12.2 A / 11.5 A
- Max. input current
- 15.2 A / 14.4 A
- Max. input current
- 18.2 A / 17.3 A
- Max. input current
- 22.8 A / 21.7 A
- Max. input current
- 30.4 A / 28.8 A
- Rated input voltage
- 3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
- Rated input frequency
- 50 Hz / 60 Hz
Efficiency
- Maximum efficiency
- ≥ 97.7%
- European efficiency
- 96.1%
- European efficiency
- 96.6%
- European efficiency
- 97.1%
- European efficiency
- 97.2%
- European efficiency
- 97.2%
- European efficiency
- 97.3%
- European efficiency
- 97.3%
Protection
- Surge protection
- DC Type II / AC Type II (Optional)
- Output circuit overcurrent protection
- Yes
- Insulation resistance monitoring
- Yes
- Residual current detection
- Yes
- Built-in PV switch
- Yes
- DC reverse polarity protection
- Yes
- Ingress protection / overvoltage category
- I / II
- Built-in AFCI module
- Yes
- Anti-islanding protection
- Yes
General data
- Max. power per phase (grid and backup)
- 50%
- Dimensions (W × H × D)
- 850 × 400 × 265 mm
- Weight
- 35 kg
- Weight
- 35 kg
- Weight
- 35 kg
- Weight
- 35 kg
- Weight
- 35 kg
- Weight
- 38 kg
- Weight
- 38 kg
- Inverter topology
- Non-isolated
- Operating temperature range
- -30 ~ +60°C (Derated above 45°C)
- Relative humidity
- 0 - 95%
- Ingress protection (IP)
- IP66
- Noise level (typical)
- <35 dB(A) (@ Rated Power)
- Noise level (typical)
- <35 dB(A) (@ Rated Power)
- Noise level (typical)
- <35 dB(A) (@ Rated Power)
- Noise level (typical)
- <35 dB(A) (@ Rated Power)
- Noise level (typical)
- <35 dB(A) (@ Rated Power)
- Noise level (typical)
- <55 dB(A) (@ Rated Power)
- Noise level (typical)
- <55 dB(A) (@ Rated Power)
- Cooling method
- Natural cooling
- Cooling method
- Natural cooling
- Cooling method
- Natural cooling
- Cooling method
- Natural cooling
- Cooling method
- Natural cooling
- Cooling method
- Smart fan cooling
- Cooling method
- Smart fan cooling
- Max. operating altitude
- 4000 m (Derated above 2000 m)
- Grid connection standard
- G98, G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, CEI 0-21, C10/11, IEC 62116, IEC 61727, IEC 60068, IEC 61683
- Safety / EMC standard
- IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3
Features
- DC connection
- MC4 Quick connection plug (PV)
- AC connection
- Quick connection plug
- Display
- LED
- Communication
- RS485, Optional: Wi-Fi, LAN, Ethernet, DI × 2 / DO × 2 / DRM
Documentation and certificates
-
DownloadDatasheet
All-in-One система Solis FlexAIO S7-EH3P (5–20) кВт · 6–54 кВт·год · трифазна.pdf
Frequently asked questions
-
Start from the site's average daily consumption and the peak load the inverter has to carry in off-grid mode. The power range of each modification and the recommended PV array size for it are listed in the product card under "Key specifications" — for a precise selection, contact a Solis dealer or use the form below.
-
The list of validated batteries is published on the product page — in the compatible-equipment section, where one has already been compiled for that model. The voltage range (LV or HV, depending on the series) is stated in the technical specifications either way. If there is no list, or the battery you need is not on it, contact the Solis Ukraine technical department — compatibility should be confirmed separately.
-
Most Solis hybrid and off-grid inverters support connecting a generator with automatic start-up when the battery is discharged. Whether a specific model has this function, and how it is wired, is stated under "Key features" and in the "Technical specifications" table of the product card.
-
It depends on the series: single-phase models are designed for a 220 V grid, three-phase models for 380/400 V. The exact connection type for a given product is stated in the "Grid phases" card under "Key specifications".
-
Solis equipment carries the manufacturer's warranty, which in Ukraine is administered by official dealers and authorised service centres. The exact term and conditions are stated on the warranty card and on the device's rating plate — for registration and the claim procedure, see the Support section.
Didn't find your answer?
The Solis Ukraine technical department advises on equipment compatibility, wiring diagrams and system configuration.